Voice Coil Driven Stage
VCDS-025-038-02-F1-01

Comparison Table


 

Voice Coil Driven Stage with Quadrature Position Sensor and Home Switch

  • Range of Motion: 0.97” (24.6 mm) 
  • Positioning Resolution: 1 microns
  • Continuous Force: 1.0 lb (4.6 N)
  • Intermittent Force: 3.2 lb (14.4 N) at 10% duty cycle
  • Optional Return Spring
  • Cross Roller Bearing
  • Quadrature Optical Encoder with Differential Outputs
  • Built-in Home Switch

Cable is not included and is sold separately
Optional cables CBL-01 or CBL-04
VCDS-025-038-02-F1-01
Enlarge
Datasheet in PDF
Drawing quick view
  
 

STAGE SPECIFICATIONS

Intermittent Force @ 10% Duty Cycle

14.4 N

3.2

lb
Continuous Force 4.6 N

1.0

lb

Force Constant

3.9 N/A

0.88

lb/A
BACK EMF Constant 3.9 V/M/S

0.10

V/in/S

Stroke

24.6 mm

0.97

in
Moving Mass 130 gr

4.6

oz

Total Mass

529 gr

18.7

oz

Coil Resistance

7.4 Ohm

Coil Inductance at 1000 Hz

2.5 mH

Continuous Power

10 W

Pin Assignment

Pin

Description

1

+5 VDC Power

2

A- Channel of Quadrature Encoder

3

B+ Channel of Quadrature Encoder

4

A+ Channel of Quadrature Encoder

5

Return for +5 VDC Power

6

Reference Signal, Active High

7

B- Channel of Quadrature Encoder

8

Motor Minus

9

Motor Plus

 Customized solutions can be provided upon request.